Energy Saving Transformer Series

Amorphous Alloy Transformer

The Amorphous Alloy Transformer is a kind of power distribution equipment with new technology for energy saving. The energy saving efficacy is mainly from the novel iron-based amorphous alloy material with excellent soft magnetic properties. The application scope of the amorphous alloy transformer is as wide as that of the oil-immersed distribution transformer. It is widely used for reconstruction of urban and rural power grids, wind power plants, oil fields’ exploitation, etc.

  • Capacity

    L x W x H (mm)

    Total Weight (kg)

    30

    990 x 860 x 810

    420

    50

    1020 x 810 x 840

    535

    63

    1060 x 820 x 865

    595

    80

    1050 x 865 x 860

    660

    100

    1110 x 880 x 920

    770

    125

    1150 x 880 x 950

    860

    160

    1210 x 880 x 965

    990

    200

    1265 x 895 x 1015

    1110

    250

    1310 x 895 x 1060

    1275

    315

    1365 x 835 x 1105

    1470

    400

    1370 x 1030 x 1195

    1835

    500

    1385 x 1125 x 1195

    2130

    630

    1505 x 1305 x 1295

    2610

    800

    1900 x 1175 x 1395

    3090

    1000

    2115 x 1275 x 1420

    3570

    1250

    2140 x 1490 x 1440

    4140

    1600

    2310 x 1560 x 1530

    4950

    In case of any change in the external dimensions and weight provided in the instructions due to technical improvement,

    the actual product shall prevail.

  • 1. Low Noise: compact design structure, application of new materials and new process, noise reduction, no oil conservator, height lower than that of similar products. Oil change is not required within the normal life, which improves the safety and reliability of power grid operation.

    2. Vacuum oil filling process is adopted for transformer sealing, which completely removes the dampness in the transformer oil tank. The transformer is not in contact with air after sealing, which effectively prevents the decline in insulation property (insulation material and oil aging) caused by the oxygen and moisture entering the transformer. Therefore, oil sample test does not need to be conducted regularly.

    3. Reliable Long Service Life: the bolted connecting structure is adopted for the fully sealed box cover and box edge, so as to isolate contact between oil and air. Insulation will not be affected with damp, which greatly reduces insulation aging speed and improves service life.

    4. Small Size and Artistic Outline. The corrugated plate heat sink is adopted for S (B) H15 series carburetor. In case of any change in the oil temperature, changes in oil volume shall be adjusted through the elastic expansion and contraction of the corrugated plate for compensation. The corrugated tank has an artistic outline, small size and floor area.

    5. No Lifting Core Inspection: it is not required to check the lifting core before operation of the fully sealed transformer, and the user can save the expense for lifting core inspection.

    6. Maintenance-free: maintenance is not required.

  • Table 1 Performance Parameters of the Amorphous Alloy Transformer with Primary Rated Voltages of 6kV and 10kV

    Rated 

    Capacity 

    (kVA)

    Voltage Combination

    Connection Unit Symbol

    Loss

    No-load 

    Current (%)

    Short-circuit 

    Impedance (%)

    Primary 

    Voltage (kV)

    Primary Voltage Tapping Range (%)

    Secondary Voltage (kV)

    No Load W

    Load W

    30

    6
    6.3
    10
    10.5
    11

    ±5
    ±2×2.5

    0.4

    Dyn11

    33

    630/666

    1.5

    4

    50

    43

    910/870

    1.2

    63

    50

    1090/1040

    1.1

    80

    60

    1310/1250

    1.0

    100

    75

    1580/1500

    0.9

    125

    85

    1890/1800

    0.8

    160

    100

    2310/2200

    0.6

    200

    120

    2730/2600

    0.6

    250

    140

    3200/3050

    0.6

    315

    170

    3830/3650

    0.5

    400

    200

    4520/4300

    0.5

    500

    240

    5410/5150

    0.5

    630

    320

    6200

    0.3

    4.5

    800

    380

    7500

    0.3

    1000

    450

    10300

    0.3

    1250

    530

    12000

    0.2

    1600

    630

    14500

    0.2

    Table 2 Insulation Level

    Rated Voltage (kV)

    Rated Short-term Power Frequency
    Withstand Voltage (kV)

    ≤1

    3

    3

    10

    6

    20

    10

    35

    15

    38

    20

    50

    35

    70

  • 1. Ultra-low loss, energy saving and high power efficiency;

    2. The characteristics of ultra-low loss and low energy are utilized during manufacturing of the amorphous metal material, which can substantially save power consumption, reduce electricity output of the power plant, relatively reduce CO? SO? emissions, and minimize environmental pollution and greenhouse effect, be maintenance-free and pollution-free;

    3. Low operating temperature, slow insulation aging and long service life of the transformer;

    4. High overload capability, high mechanical strength;

    5. When the amorphous iron core passes through magnetic flux with higher frequency, it still has the characteristics of low iron loss and low exciting current, so as to avoid iron core saturation. Therefore, the S (B) H15 Amorphous Alloy Transformer with amorphous iron core has good resistance to harmonic wave;

    6. Rapid returns on investment.

  • 1. The elevation shall not exceed 1,000m

    2. Ambient Temperature Maximum Temperature           +40℃/104℉

                         Maximum daily average temperature       +30℃/86℉

                         Maximum annualaverage temperature     +20℃/68℉

                         Minimum temperature                               -30℃/-22℉(applicable for the outdoor transformers)

                         Minimum temperature                               -5℃/23℉(applicable forthe indoortransformers)

    3. The waveform of the supply voltage is similar to sine wave

    4.The supply voltage connected with the multi-phase transformer shall be approximately symmetrical.

Contact information

Submit your inquiry
Name:
Your message:
Phone:
E-Mail:
Company:
Name:
Country:
   

Your local Huaxin Sales Team

  • NameKai Wang
  • Address813 46th Street East, Saskatoon, Saskatchewan S7K 0X1, Canada
  • PhoneChina:15234310529,Canada:+1 (306) 713-2408
  • FaxChina:+86 (0)353-4909788
Close
Submit your inquiry
Name:
Your message:
Phone:
E-Mail:
Company:
Name:
Country:
   

Your local Huaxin Service Team

  • NameKai Wang
  • Address 813 46th Street East, Saskatoon, Saskatchewan S7K 0X1, Canada
  • PhoneChina:15234310529,Canada:+1 (306) 713-2408
  • FaxChina:+86 (0)353-4909788
Close
Submit your inquiry
Name:
Your message:
Phone:
E-Mail:
Company:
Name:
Country:
   

Your local Huaxin Cooperation Team

  • NameKai Wang
  • Address813 46th Street East, Saskatoon, Saskatchewan S7K 0X1, Canada
  • PhoneChina:15234310529, Canada:+1 (306) 713-2408
  • FaxChina:+86 (0)353-4909788